The TCM CombiM configuration is designed specifically for neonatal and pediatric intensive care needs. It provides continuous, reliable, accurate, non-invasive and real-time transcutaneous tcpO2 and tcpCO2 information and comes with a range of high performing sensors.
TCM Combi M Monitor
The TCM CombiM configuration is designed specifically for neonatal and pediatric intensive care needs. It provides continuous, reliable, accurate, non-invasive and real-time transcutaneous tcpO2 and tcpCO2 information and comes with a range of high performing sensors.
ThetcpO2 measurement, a differentiating feature of the TCM CombiM monitor, is a crucial parameter for patients in neonatal intensive care to avoid the risk of hyperoxia and its effects (eg. retinopathy in preterm babies). Indeed for high oxygenation rate, where SpO2 is not any more accurate, tcpO2 carries on providing a precious information concerning oxygenation of the tissue.
The TCM CombiM monitor combines an enhanced ready-to-use function with a unique gold-plated sensor technology in the tc Sensor 84 and tc Sensor 54, making it highly reliable, stable and robust. Real-time trending of measured parameters is displayed ensuring fast and immediate clinical intervention to critical changes.
The TCM CombiM monitor utilizes various communication protocols to interface with any patient monitoring system and PC. Optimize your work routines
Intuitive color touch screen and Windows CE software for increased user-friendliness
High compatibility to interface with any patient monitoring system
On-board video tutorials
Built-in battery facilitates transport of the patient
Simultaneous viewing of all measurements
USB port for easy printing of reports
Patient-friendly sensor fixations for improved comfort
Increased patient safety
On-screen visualization of patient data in graphical or tabular format
Patient information automatically linked to measurements
Automatic linking of data and marking of events to a session
Real-time data storage
Continuous trend measurement
Radiometer offers a broad range of syringes and capillary tubes for safe blood gas collection and analysis.
Our sampler line plays an integral role in securing workflow efficiencies when it comes to acute care testing.
Samplers
Radiometer offers a broad range of syringes and capillary tubes for safe blood gas collection and analysis.
Our sampler line plays an integral role in securing workflow efficiencies when it comes to acute care testing. All syringes and capillary tubes are safety-engineered to eliminate preanalytical errors and protect caregivers from needlestick injuries or unnecessary contact with blood.
With our uniquely formulated electrolyte-balanced heparin, you are consistently ensured a high analytical quality of your blood gas testing.
Correct patient-sample match and correctly identified results
Incorrect or missing patient IDs are some of the most frequent and critical errors, leading to resampling, or worse, misdiagnosis and incorrect treatment. Each PICO syringe is prebarcoded to guarantee correct patient identification every time. With Radiometer's data management system, you can even scan and link together sample and patient IDs directly at the bedside.
Quickly remove air bubbles and avoid blood contact
The unique self-sealing design of oursafeTIPCAP simplifies the removal of air bubbles and limits the risk of contact with patient blood, including during transport and analysis.
Ensure fast, standardized mixing and prevent sample clotting
All safePICO syringes have a built-in metal mixing ball, ensuring fast and homogeneous mixing of the sample. Our dry electrolyte-balanced heparin is dispersed throughout the sample to prevent clots, while minimizing bias on all electrolytes.
Needle shield device for maximum safety
Operator safety is crucial in all phases of acute care testing. The integrated needle shield device on safePICO self-fill syringes allows for single-handed removal of the needle without the risk of needlestick injury.
Designed for maximum flexibility - safePICO syringes come in different models to suit your needs:
- safePICO aspirator for a-line sampling
- safePICO self-fill for arterial puncture sampling
Radiometer 's safeCLINITUBES and CLINITUBES come in a variety of sizes to match the sample-volume requirements of different analyzers. Design increases safety for caregivers
The rounded ends of the capillary tubes increase safety for patients and staff while the vented capillary cap guarantees safe sealing and minimizes the risk of blood spillage. The capillary tubes come with a mixing wire and magnet to facilitate thorough mixing of the sample. safeCLINITUBES are made of 100 % environmentally friendly plastic eliminating the risk of breakage, staff or patient injury and contamination. CLINITUBES have a strong glass construction and are durable, gas-tight and resistant to breakage.
Fast filling time convenient for clinicians and patients
Capillary samples are often collected in stressful situations, making it difficult to fill a capillary tube with a single puncture. A unique surface treatment ensures fast filling, making sampling procedures easier for clinicians and less uncomfortable for your patients.
High accuracy and reduced risk of clotting
All our capillary tubes are preheparinized with dry electrolyte-balanced heparin, significantly reducing the risk of clotting and securing reliable results without any bias on electrolytes.
TCM TOSCA Monitor
TCM 400 monitor
The TCM TOSCA monitor is used for continuous monitoring of the ventilatory status and oxygen saturation in pediatric and adult patients e.g. in respiratory care and sleep medicine.
TCM TOSCA Monitor
The TCM TOSCA monitor is used for continuous monitoring of the ventilatory status and oxygen saturation in pediatric and adult patients e.g. in respiratory care and sleep medicine.
TCM TOSCA is an easy-to-use solution designed to monitor tcpCO2, SpO2 and pulse rate through a single sensor. The integrated Masimo SET technology for pulse oximetry provides accurate monitoring of oxygen saturation even during motion and at low perfusion.
The TCM TOSCA monitor can be connected to polysomnographs for overnight monitoring of the ventilation and oxygen saturation in sleep medicine.
The tc Sensor 92 comes with a convenient clip to attach the sensor to the ear, providing optimal comfort to the patient during monitoring. Optimize your work routines
Intuitive color touch screen and Windows CE software for increased user-friendliness
High compatibility to interface with polysomnographs
On-board video tutorials
Built-in battery facilitates transport of the patient
Simultaneous viewing of all three measurements
USB port for easy printing of reports
Ear clip sensor fixation for optimal patient comfort
Alternative sensor fixation ring
Increased patient safety
On-screen visualization of patient data in graphical or tabular format
Fast entry of patient name and ID using on-screen keyboard
Patient information is automatically linked to measurements
Option to insert predefined textual event during measurements
Automatic linking of data and marking of events to a session
Real-time data storage
Continuous trend measurement
The more measurement sites on the patient, the more information you get to make the right clinical decision for patients suffering from vascular diseases.
TCM 400 Monitor
The more measurement sites on the patient, the more information you get to make the right clinical decision for patients suffering from vascular diseases.
The TCM400 monitor is the only portable unit providing up to six simultaneous measurements of transcutaneous oxygen tension (tcpO2). In combination with the high performing pO2 sensor, the tc Sensor E5250, the TCM400 monitor offers reliable, accurate, non-invasive and real-time measurements even at sites of the body with poor perfusion.
By non-invasively providing accurate quantitative information about cutaneous oxygenation and perfusion, the TCM400 monitor is a valuable diagnostic tool in a variety of clinical settings.
Optimize your work routines
Intuitive color touch screen and Windows CE software for increased user-friendliness
On-board video tutorials
Built-in battery facilitates transport between patients
Simultaneous viewing of all six measurements
Immunoassay – AQT 90 Flex Analyzer
ABL 80 Flex Analyzer
Offering a comprehensive cardiac panel and markers for coagulation, infection and pregnancy, the AQT90 FLEX analyzer streamlines testing and supports fast clinical decision-making when time is of the essence.
Immunoassay – AQT 90 Flex Analyzer
Powering your critical decisions
Offering a comprehensive cardiac panel and markers for coagulation, infection and pregnancy, the AQT90 FLEX analyzer streamlines testing and supports fast clinical decision-making when time is of the essence.
The safe PICO Mixer, a portable and automated mixing device, ensures fast and standardised mixing of the sample prior to analysis on any of the ABL80 FLEX analyser series. Automated mixing saves time and reduces the risk of preanalytical errors.
ABL 80 Flex Analyzer – BLOOD GAS ANALYZER
Automated sample mixing
The safePICO Mixer, a portable and automated mixing device, ensures fast and standardised mixing of the sample prior to analysis on any of the ABL80 FLEX analyser series. Automated mixing saves time and reduces the risk of preanalytical errors.
No contact with blood or waste On the ABL80 FLEX analysers, you and your staff can avoid contact with blood or waste. Samples are automatically aspirated and blood waste stays in the closed solution pack.
The ABL80 FLEX analyser series comes in different models to meet different diagnostic needs.
For many smaller clinics and hospital departments, the ABL80 FLEX BASIC version offers a cost-effective way to improve patient treatment with minimal investment. For larger clinics and hospitals, the ABL80 FLEX and the ABL80 FLEX CO-OX units provide quality, reliability and comprehensive benchtop features.
The ABL80 FLEX CO-OX OSM version provides short turnaround time and accurate test results on co-oximetry parameters and is ideal for use in Cath labs, EDs and the NICU. The ABL80 FLEX CO-OX OSM version analyser includes hemolysation of blood for improved accuracy versus non-hemolysed blood.
All versions include:
Large color touch screen for easy operation
Customisable interface and manager control settings
Portability and fully operational on battery
Full LIS/HIS connectivity
Integrated barcode reader
Small and portable
Lightweight and fully operational on battery, you can take the ABL80 FLEX series of analysers anywhere. That means a single analyser can be used in several departments.
Easy to use
The ABL80 FLEX analyser’s intuitive user interface can be configured to your needs. A parameter bar provides analyser status at a glance, while multimedia tutorials offer immediate assistance at the touch of the screen. For fast entry of patient and sample data and reduced risk of errors, use the integrated barcode reader.
Simple and fast replacement of consumables
With its convenient cassette format, the ABL80 FLEX analyser series requires minimum maintenance. Smart chips simplify the replacement of both the solution pack and sensor cassette. And the analyser is ready for use just a few minutes after a consumable replacement.
The ABL80 FLEX analyser and the ABL80 FLEX CO-OX analyser offer automatic quality control (QC) to ensure reliability of testing performed at the point of care and document regulatory compliance.
The comprehensive built-in QC3 system measures on three aqueous QC solutions, covering a broad portion of the reportable range. System checks are continually performed monitoring the analyser's performance.
Automatic corrective actions are initiated where necessary, ensuring you are inspection-ready at a moment's notice. QC measurements cover low, normal and high reportable ranges
Low
Normal
High
With Radiometer's QA Portal you can collect, process, report and archive QC data from your analysers placed throughout the hospital, making regulatory compliance even more convenient. With the Worldwide DATACHECK (WDC) program you can perform online peer group comparisons of your QC results whenever and as often as you like.
Test Menu
On the ABL80 FLEX analyser series, sensor cassettes are available with several parameter panels and multiple test volumes to match your diagnostic needs.
Type
Para-
meters
Units
Measuring
range
Test
range
pH
pH
pH scale
6.00-8.00
7.00-7.70
Blood gas
pCO2
mmHg
kPa
0-150
0-0-20-0
15-125
2.0-16.7
-
pO2
mmHg
kPa
0-760
0.0-101.3
14-420
1.9-56.0
Electrolytes
cK+
mmol/L
meq/L
0.0-20.0
0.0-20.0
2.0-8.0
2.0-8.0
-
cNa+
mmol/L
meq/L
0-210
0-210
120-180
120-180
-
cCa2+
mmol/L
meq/L
mg/dL
0.00-5.00
0.00-10.00
0.00-20.00
0.50-2.50
1.00-5.00
2.00-10.00
-
cCl-
mmol/L
meq/L
0-250
0-250
85-140
85-140
Glucose
cGlu
mmol/L
mg/dL
0.0-75.0
0-1351
2.0-40.0
36-720
Hematocrit
Hct
%
0-85
10-75
Oximetry
ctHb
g/dL
d/L
mmol/L
0.0-27.7
0-277
0.0-17.2
7.0-25.0
7.0-250.0
4.3-15.5
-
sO2
%
Fraction
0.0-100.0
0.000-1.000
0.0-100.0
0.000-1.000
-
FO2Hb
%
Fraction
0.0-100.0
0.000-1.000
0.0-100.0
0.000-1.000
-
FCOHb
%
Fraction
0.0-100.0
0.000-1.000
0.0-20.0
0.000-0.200
-
FMetHb
%
Fraction
0.0-100.0
0.000-1.000
0.0-20.0
0.000-0.200
-
FHHb
%
Fraction
0.0-100.0
0.000-1.000
0.0-100.0
0.000-1.000
The Measuring rangeis defined as the limits within which the analyser is capable of displaying parameter values.
The Test range for a parameter is the range within which accuracy and precision of a measured parameter was specified by the manufacturer.